IQmark Diagnostic Workstation Operation Manual
4
B. Thin Client Configuration
If you have a thin client environment, you can install the IQmark Diagnostic Workstation
software on the Terminal Server and operate the IQmark Digital ECG and/or the IQmark
Digital Spirometer through a thin client terminal.
The IQmark Diagnostic Workstation supports two thin client configurations. The IQmark
Virtual Channel Solution is appropriate when using Microsoft Windows based PCs as
clients. In this configuration, you can use either the USB or serial port versions of the
IQmark Digital ECG and IQmark Digital Spirometer products in high latency, limited
bandwidth network configurations. The following section describes the virtual channel
solution. The second possible configuration is to use the serial port version of the IQmark
Digital ECG, IQmark Digital Spirometer and IQmark VSM products and connect them to
client devices via COM port mapping. This configuration is appropriate when using non-
Windows thin client devices on low latency high-speed networks. The section entitled
Thin Client Using COM Port Mapping discusses this solution.
Setting up any application on a network environment typically requires special access
rights and knowledge of the network. Please have your network administrator install and
setup the IQmark Diagnostic Workstation to fit your office environment.
Thin Client Using the IQmark Virtual Channel Solution
The IQmark Thin Client Virtual Channel software provides the following advantages
over COM port mapping.
1. Operation over high latency, low bandwidth, high loss networks. For Microsoft
Terminal Services, the virtual channel provides a 10 to 1 improvement in
performance in latency tolerance over COM port mapping. For Citrix ICA the
performance improvement is approximately 40 to 1 in latency tolerance.
2. No COM port mapping is required.
3. It is possible to use the USB versions of the ECG and Spirometry modules.
4. Improved device auto-configuration and diagnostics.
NOTE: The IQmark Virtual Channel Solution has specific requirements for
computer hardware, software and network performance. System
administrators must read the document entitled Application Note: Using
the IQmark Thin Client Virtual Channel Software before installing,
configuring and using this software in a thin client environment.
The following block diagram describes the IQmark Virtual Channel Solution. In this thin
client environment, the client computers must be running Windows XP SP2 or Windows
Vista.